Revision as of 06:38, 17 June 2026 by CelesteG04 (talk | contribs) (Created page with "Protect Against Insurance Claims & NCC Compliance Failures <br>The displacement volume test method is a useful test alongside a ramp test where the surface is severely profile...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Protect Against Insurance Claims & NCC Compliance Failures
The displacement volume test method is a useful test alongside a ramp test where the surface is severely profiled or structured and designed to provide drainage or entrapment of contaminants. While the measurement of slip resistance using wet methods is achieved with Appendices A, C and D, the inherent slip resistance value (uncontaminated surface) is achieved with the dry test (Appendix B) and is the only method suitable for testing under dry conditions. These four slip resistance test options provide an assessment of the contribution of a pedestrian Independent Testing Australia surface to the risk of slipping to assist in the specification of a surface material for most pedestrian applications. This test is more suited to profiled or textured surfaces and may provide a classification of either R9, R10, R11, R12 or R1


This encompasses information relating to the exposure conditions, time, specimen preparation, and any measurable or observable effects. This information measures resistance to UV degradation and is used to formulate products or choose materials. The overall exposure time varies according to the application and the resistance requirement of the material. Temperature, humidity, and water spray conditions must be adequately maintained.
All cycles vary between 4-hour or 8-hour light and 4-hour condensation periods, except for some minor differences in cycle 5 (20 h light) and cycle 7 (15 min spray). An ASTM G154 UV test chamber, or a QUV test chamber, is equipment used for simulating the degradative effects of sunlight and water on materials. UV-B lights tends to accelerate or create "brittleness" or an ageing process not typically occurring outdoors. UV-A bulbs can offer Daylight and UV behind window glass exposures.UVA-340 offfers the best correlation to outdoor exposures because it is the best simulation of sunlight from 295 to 365 n

Characterisation is an important aspect in membrane research and can be conducted on the membrane material, the fouling material adhering to the surface of the membrane or fluid that is passing through the membran

Research has indicated that TRL rubber may provide a better indication of barefoot slip resistance due to the softer yielding nature of the material, being more comparable to human skin than Four S rubbe


Q-Lab can help you determine the best comprehensive test plan for your products and materials. These two test types are complementary and, performed together, make up a complete weathering test program. Water can be present in the form of dew (condensation), relative humidity, and rainfall. Water can also cause physical effects like erosion, absorption, freeze/thaw stress, thermal shock, and material loss from impact. Browse our weathering industries pages and case studies for examples of weathering durability testing, or check out this general testing guid


Our slip ratings that we apply to flooring surfaces are endorsed by the National Association of Testing Authorities (NATA) ensuring quality and consistency by qualified scientists that you can rely on. Get in touch using the form below and our experts will get in contact soon! Interested in slip resistance testing or consulting for your organisation? Tests and reports are conducted using Australian and International Standards as well as The National Construction Code. Working with QED, the only NATA accredited laboratory in WA to perform and report on slip tests means our reporting is assured by an independent third party. Ongoing monitoring of in-situ flooring is conducted according to AS 4663 Slip resistance measurement of existing pedestrian surface


Our technicians are highly trained and utilise the latest technology available including wet pendulum tests to ensure our clients have peace of mind and comply with their insurer’s requirements. Our team also performs regular onsite slip testing and slip accident investigations, public liability risk assessments and we provide expert witness evidence in slip and fall accidents. Our technicians are highly trained and utilise the latest technology available including wet pendulum tests to ensure our clients have peace of mind Our experts are scientists and safety consultants, many with post graduate qualification to provide in depth understanding and reducing your risk as a specifier, or construction compan


In Australia, slip resistance is Independent Testing Australia assessed under AS 4586 testing methods, which classify flooring based on performance in dry, wet or greasy environments. Forbo has over 50 years of experience in designing and manufacturing safety vinyl floor coverings.Our Step safety flooring collection is a complete range of products that meet safety requirements across a wide variety of different applications. It details slip rating requirements using methods such as the 'wet pendulum', 'oil-wet inclined ramp', and 'wet barefoot' tests, catering to various environments. Understanding AS 4586 slip ratings and how to specify compliant flooring for Australian commercial environments.
Forbo Step safety flooring ran